Metric stair calculator

A metric stair calculator lets you stay entirely in millimetres and metres, which is the natural workflow if you're building to metric drawings or living somewhere that never adopted imperial for construction. The underlying stair math doesn't change, only the units do.

This page works a full example in millimetres, gives you a conversion table for the values you'll use most, and covers the rounding habits that keep a metric layout buildable.

Metric stair calculator

Finished floor to finished floor, measured plumb.

The riser height you would like; the calculator rounds to a whole number of equal risers.

Nosing to nosing. Nosing overhang is not included.

15 risers of 180 mm, 14 treads of 270 mm, total run 3780 mm, angle 33.7°, stringer 4645 mm.

Risers

15

Riser height

180 mm

Treads

14

Tread depth

270 mm

Total run

3780 mm

Stair angle

33.7°

Stringer length

4645 mm

2R + T

630 mm

comfort ≈ 600–650 mm

Run + nosing

3805 mm

Stair side-elevation diagramSide elevation of a stair with 15 risers of 180 mm and 14 treads of 270 mm, total rise 2700 mm, total run 3780 mm, angle 33.7°.UP2700 mm3780 mm180 mm270 mm33.7°Stringer 4645 mm
Side elevation of the calculated flight (auto-scaled).

Need presets, code profiles, printing or sharing? Continue with these values.

Open in the full stair calculator

Working entirely in millimetres

Metric stair layout uses the same relationships as imperial stairs, just in millimetres and metres instead of inches and feet: risers = round(total rise ÷ target riser), riser height = total rise ÷ risers, going = tread depth, and total run = treads × going.

A typical floor-to-floor height in a metric-drawn house is around 2700 mm, though this varies by region and floor construction just as much as imperial floor-to-floor heights do. Always take your actual measurement rather than assuming a standard.

Common riser and going ranges

Riser height on a metric domestic stair is commonly cited in the 170 to 180 mm range, and going (the metric term for tread depth) in the 250 to 280 mm range. These are typical, commonly seen figures, not universal minimums or maximums, since exact limits depend on the building regulations that apply where you're building.

A taller riser paired with a shorter going gets you up a floor in fewer steps but feels steeper; a shorter riser with a deeper going feels gentler but takes up more floor area. The Blondel check below is the usual way to balance the two.

Blondel's formula in millimetres

Blondel's comfort formula translates directly: 2R + G, where R is riser height and G is going, both in millimetres. It's commonly targeted at roughly 600 to 650 mm total, aiming for a stride that matches a natural walking pace on the flat.

For a 180 mm riser and 270 mm going: 2(180) + 270 = 630 mm, which sits comfortably inside that range.

Metric comfort check
Riser (mm)Going (mm)2R + G (mm)
170280620
175270620
180270630
190250630

Inch to millimetre conversion table

If you're translating between an imperial plan and a metric one, or checking a metric result against imperial reference numbers, these are the conversions you'll reach for most often.

Common stair values in inches and millimetres
InchesMillimetres
7 in (riser)≈ 178 mm
7¼ in (riser)≈ 184 mm
10 in (going)≈ 254 mm
10½ in (going)≈ 267 mm
1 in (nosing)≈ 25 mm
9 ft (floor-to-floor)≈ 2743 mm

Rounding to whole millimetres

Once you've calculated an exact riser height, round it to a whole millimetre for the layout, and don't try to hold a tolerance tighter than about 1 mm between risers, since that's below what a tape or story pole can reliably repeat on site.

The commonly cited variation limits between adjacent risers in imperial code language (around 10 mm, roughly equivalent to the ⅜ in figure used in the US) are a useful target to hold yourself to even where local rules are phrased differently.

  1. Calculate exact riser height from total rise ÷ number of risers.
  2. Round to the nearest whole millimetre for the story pole and stringer layout.
  3. Cut a test riser and confirm it against the story pole before cutting the full set of stringers.

Common metric board sizes

Metric-market stair stock is typically sold in round millimetre widths and thicknesses rather than nominal lumber sizes: treads commonly come in 32 mm or 40 mm finished thickness, and stringer or string material is often supplied in 250 to 300 mm widths to give enough depth for a full-height cut string.

If you're sourcing from an imperial supplier for a metric-designed stair, convert your target board sizes to the nearest stocked imperial size rather than assuming an exact millimetre match is available off the shelf.

Worked math

Worked example: 2700 mm floor-to-floor, 175 mm target riser, 270 mm going

Given

  • Total rise: 2700 mm
  • Target riser: 175 mm
  • Going: 270 mm

Steps

  1. Risers = round(2700 ÷ 175) = round(15.4) = 15
  2. Riser height = 2700 ÷ 15 = 180 mm
  3. Treads = 15 − 1 = 14
  4. Total run = 14 × 270 = 3780 mm
  5. Angle = atan(180 ÷ 270) = 33.7°
  6. Stringer length = √(2700² + 3780²) ≈ 4645 mm
  7. Blondel check = 2(180) + 270 = 630 mm, inside the commonly cited 600–650 mm range

15 risers at 180 mm, 14 goings at 270 mm, a 33.7° angle, and a 4645 mm stringer length, with a Blondel result of 630 mm.

Questions

Metric stair calculator FAQ

What is a typical riser height in metric stairs?

Riser height on a metric domestic stair is commonly cited in the 170 to 180 mm range. It varies by the building regulations that apply in your location, so check local guidance for exact limits.

What is 'going' in a metric stair calculation?

Going is the metric term for tread depth, the horizontal distance from the nosing of one tread to the nosing of the next. It's commonly cited in the 250 to 280 mm range for domestic stairs.

How do I convert inches to millimetres for a stair layout?

Multiply the inch value by 25.4. A 7¼ in riser is about 184 mm, a 10½ in tread is about 267 mm, and a 9 ft floor-to-floor height is about 2743 mm.

What is Blondel's formula in millimetres?

The same relationship as the imperial version, just in millimetres: 2 × riser height + going, commonly targeted at roughly 600 to 650 mm total for a comfortable stride.

Should I round metric riser heights?

Yes, round the calculated riser height to the nearest whole millimetre for layout purposes, since tighter tolerances than that are difficult to hold reliably with a tape measure or story pole on site.

What thickness are metric stair treads usually sold in?

Finished tread stock is commonly available in 32 mm or 40 mm thicknesses, with string or stringer material often supplied in 250 to 300 mm widths.

Can I use this calculator for both metric and imperial stairs?

Yes, the underlying formulas are unit-independent. Switch to metric mode to enter and read results in millimetres, or use the imperial version of the tool if you prefer inches.

Keep going

Important

Disclaimer

StairCalculator.app provides calculations and educational information. Building codes and construction requirements vary by location. Verify final dimensions and requirements with the applicable local building authority or qualified professional.

Calculations are only as accurate as the measurements and inputs you provide; small errors in measuring total rise or floor thickness can shift the results, so double-check field measurements before cutting materials, and treat every reference value and worked example on this site as illustrative rather than a guarantee of code compliance.